NeuroPlan

NeuroPlan™: The System for Functional Neurosurgery

NeuroPlan™ consists of several Radionics instrumentation and software packages integrated into a single, comprehensive system ideal for functional neurosurgery.

  • The CRW™ Stereotactic System offers unparalleled stability and quality assurance.

  • StereoPlan™ software supports both target and trajectory planning in 3-D.

  • AtlasPlan™ software provides target confirmation with anatomic detail from a trusted source.

  • ImageFusion™ software provides true volumetric image matching and image freedom.

  • The RFG-3CF™ lesion generator offers safety parameters ensuring dependability through all phases of stimulation and lesion generation.

Committed to Service

With thousands of centers worldwide using Radionics products, we have the experience to understand our customers' needs.

As part of the Radionics commitment to your facility, we provide extensive service features to all product users. We realize that service is often required at critical junctures during surgery and we do everything possible to solve the problem and ensure optimal functionality of your Radionics system at all times.

Our service features include:
  • Complete on-line modem support for troubleshooting and software revisions.
  • Extended telephone support, provided by Radionics engineers committed to solving problems quickly and effectively
  • Site visits, when necessary, to supplement telephone and modem support.
  • Offices worldwide to support all of our customers' needs promptly and efficiently.

All components of the NeuroPlan™ system are fully compatible with the OmniSight™ EXcel image guidance system and the XKnife™ stereotactic radiosurgery and radiotherapy system.

Follow this procedure timeline:

An example of a typical functional case with the NeuroPlan™ System

A Prior Day:MRI scan without any frames
8:00 AM:CRW™ frame fitting
8:30 AM:CT scan; patient is taken to pre-op; images are transferred to NeuroPlan™ workstation
9:50 AM:Correlate the CT and MR images utilizing ImageFusion™
9:55 AM:Verify ImageFusion™ results
10:00 AM:Develop optimal plan for target and trajectory utilizing StereoPlan™ Software
10:20 AM:Confirm target using AtlasPlan™
10:30 AM to 11:00 AM:Patient set-up and preparation
11:00 AM:Insert cannula and recording electrode
11:10 AM:Initiate recording; confirm target
12:00 PM:Conclude recording

Next Options - At this stage of the procedure, the patient will undergo either lesioning, or deep brain stimulator (DBS) implantation. The NeuroPlan™ System fully supports either treatment option.

12:00 PM to 12:30 PM:Stimulation/Test Lesioning
12:30 PM to 1:00 PM:Lesioning
1:00 PM:Closing, patient taken to post-op
or
12:00 PM to 12:30 PM:DBS placement and testing
12:30 PM to 1:00 PM:DBS implant fixation

CAUTION: Federal (USA) law restricts this device to sale by or on the order of a physician.